FA REPORTS ACRID SMELL IN FA BUNK AND ALSO CHEC ED PILOT AREA. LOCATED CREW BUNK HEATERS AND RAN OPS CHECK OF HEATERS AND SUPPLY VALVES PER AMM 21-29-00. OPS CHECK GOOD NO DEFECTS NOTED M&L UPDATE. UPON COMPLETION OF CONDITION INSPECTION PER AMM 05-51-58-800-801-C3 STEP C. FOUND AFT GALLEY OVEN 706 WITH EXCESSIVE BURNT FOOD. REMOVED AND REPLACED OVEN 706 IN AFT GALLEY AS PRECAUTION IAW AMM 25-32-02/401. OPS CHECKED OVEN, STEAM, GOOD AT THIS TIME. NO BURNT ODOR NOTED. PERFORMED VISUAL INSPECTION TO MIX MANIFOLD, NO DEFECTS FOUND, PERFORMED INSPECTION AND OPS CHK OF BOTH OFAR & OFCR HEATER IAW AMM 21-41-10-F400-801 & 21-41-20-400-801, ALL OPS CHKD PASSED, NO SIGN OF BURNT OR SMOKE ODOR.
| Incident date | July 13, 2026 |
|---|---|
| Airline | HNAA |
| Flight | AMM21 |
| Aircraft | EMB EMB145LR |
| Registration | N928AE |
| Affected area | Cockpit |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: HNAA fumes or odor report on 2026-07-13 (external.apic4e.faa.gov)
- FAA SDR: CALA fumes or odor report on 2026-07-14 (external.apic4e.faa.gov)
- FAA SDR: HNAA fumes or odor report on 2026-07-13 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.