AVIONICS SMOKE CLIMBING THROUGH 13000. SNIFFER FAN REVEALED NO SMOKE. RETUNED MEM. SMOKE WARNING CLEARED APPROACHING BLOCKS, BUT THEN WARNING RETURNED AFTER A MINUTE. UPON SHUTDOWN AND OPENING COCKPIT DOOR WE SMELLED SMOKE IN CABIN. REMOVED AND REPLACED SMOKE DETECTOR 13WA IAW AMM 26-15-12-04. RAN ENGINES PER JRH NO AVIONICS SMOKE LIGHT ILLUMINATED. WATER ACCUMULATION CHECK COMPLIED WITH IAW AMM 05-50-01-00. ACFT OK FOR SERVICE.

Incident date May 6, 2026
Airline FDEA
Flight AMM26
Aircraft AIRBUS A300F4605R
Registration N657FE
Affected area Cockpit
Event type Smoke Warning
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.