ELECTRICAL ODOR AT 1R, IMMEDIATELY SHUT OFF FORWARD GALLEY COFFEE MAKER, OVENS, AND CHILLERS. ODOR DECREASED IMMEDIATELY BUT COULD STILL SMELL IT. SHUT OFF CABIN FANS, SELECTED HI FLOW AND AVIONICS EXTRACT TO INCREASE AIRFLOW AND SHUT OFF GALLEY POWER ODOR FINALLY DISSIPATED INITIALLY BUT CAME BACK ON AND OFF TILL LANDING. SHUT OFF PAX SYSTEM BUT DID NOT HELP, SHUT OFF GALLEY FLOOR HEATING BUT THERE WAS NO HEAT TOUCHING THE FLOOR OR A SMELL DOWN LOW. INSPECTION FOR R1 DOOR (POS 602) AND GALLEY 402 & 403 AND OVERHEAD PANEL. FOUND GALLEY 402 GAIN 1 COFFEE MAKER WIRE CHAFING AND ELEC' SMELL FROM GAIN 3 COFFEE MAKER. CONFIRMED INSIDE OF POS 402 GAIN 1&2&3 AND ACCESS TO ELECTRICAL CONNECTOR AREA NO ELEC SMELL & BURNING. ONLY SMELLING FROM GAIN 3 COFFEE MAKER. AFTER DEACTIVATED COFFEE MAKER, NO ELEC SMELL. CONFIRMED ALL FPH OPEN LOCKED POSITION PER ER/A 633237-14, REV ORG. OK TO CONT' SVC. (LP# 8506530, 8506533)
| Incident date | March 25, 2026 |
|---|---|
| Airline | DALA |
| Flight | AT1R |
| Aircraft | AIRBUS A350941 |
| Registration | N529DN |
| Affected area | Cabin |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: DALA fumes or odor report on 2026-03-25 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.