FUMES AFTER LANDING. MODERATE INTENSITY PRESENT IN FLT DECK & FWD CABIN APU ON BLEED OFF. C/W W/C 0550-2002. AFTER NR 1 ENGINE & APU INSPECTION FOUND OIL POOLING AT BOTTOM OF APU GENERATOR AND SIGNS OF DE-ICING FLUID IN APU BAY. IAW MCC REQUEST PERFORMED A LEVEL B – DECONTAMINATION OF ECS & INOP APU IAW AMM 21-00-00-615-803-A. ALL STEPS C/W BUT WILL REQUIRE R & R OF RECIRC FILTERS. C/W NO GO ODI STEPS A – I. R & R RECIRC FILTERS IAW AMM 21-21. C/W NO GO ODI LOG 1421462 STEP J AMDS CARD 0550-9001-A320FAM. (LP: 7633434)

Incident date January 27, 2026
Airline DALA
Flight NR1
Aircraft AIRBUS A319114
Registration N345NB
Affected area Engine
Event type Fumes or Odor
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.