AUDIBLE POP AND SPARKS WHEN GROUND POWER CONNECTED. BURNING ODOR SMELLED IN FLIGHT DECK. GROUND POWER PROMPTLY REMOVED. PERFORMED ELECTRICAL CHECK OF K114. PHASES A AND B BOTH SHORTED FROM INPUT TO OUTPUT. R & R CONTACTOR K114 IAW AMM 24-41. R & R EXTERNAL POWER RECEPTACLE IAW AMM 24-41. R & R PHASE A & B INTERLOCK FUSES. RAN ON APU GENERATOR AND VERIFIED NO POWER TO RECEPTACLE. CONNECTED GROUND POWER & PERFORMED SEVERAL POWER SWAPS. ALL CHECKED GOOD.
| Incident date | January 16, 2026 |
|---|---|
| Airline | DALA |
| Flight | AMM24 |
| Aircraft | BOEING 757351 |
| Registration | N583NW |
| Affected area | Cockpit |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: DALA fumes or odor report on 2026-01-16 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.