SMELLED ODOR ON TAKE OFF AND LANDING -FOUND EVIDENCE OF HYDRAULIC FLUID LEAKING FROM YELLOW SYSTEM HP MANIFOLD BAY INTO APU AIR INLET. REPLACED PACKINGS ON YELLOW SYSTEM HP MANIFOLD IAW AMM 29-13-14. OPS/LEAK CHECK GOOD. PERFORMED DECONTAMINATION OF ECS SYSTEM IAW AMM 21-00-00-615-802-A. NO SMELLS NOTED. A/C BELLY WASH ON MWI ON MDDR 125491.DESCRIPTION OF FUMES / ODOR(S)-HYDRAULIC, APPARENT CABIN SOURCE-CABIN AIR SUPPLY VENTS, VISIBLE SMOKE / HAZE-VISIBLE SMOKE / HAZE, MEDICAL ATTENTION REQUIRED-NONE
| Incident date | January 6, 2026 |
|---|---|
| Airline | GTIA |
| Flight | AMM29 |
| Aircraft | AIRBUS A320232 |
| Registration | N623NK |
| Affected area | Engine |
| Event type | Fumes or Odor |
| Verification | Official |