SMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW. REF LP 7458681 COMPLIED AMM TASK 05-51-58-800-801-C3 WITH CMC MSG 21-24700 VISUAL CHECK AND DEACTIVATED LOWER RIGHT RECIRCULATING FAN. OPERATE AIR CONDITIONING ON GROUND, NO MORE TRACES OF ODOR/SMOKE ON THE CABIN.

Incident date December 31, 2025
Airline CALA
Flight AMM05
Aircraft BOEING 777300ER
Registration N2644U
Affected area Cabin
Event type Fumes or Odor
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.