AFTER ENGINE START, CREW REPORTED ELECTRICAL BURNING SMELL WITH FAN EICAS MESSAGE DISPLAYED. BLOCK RETURN FOR INSPECTIONS AND MAINTENANCE. FOLLOWING FWD LOWER CARGO OFF LOAD, LINE MAINTENANCE ISOLATED FAULT TO FWD PRIMARY SUPPLY FAN. ADDITIONAL INSPECTIONS OF FWD EQUIPMENT SUPPLY AND EXHAUST FANS WITH ASSOCIATED WIRING SATISFACTORY. FWD EQUIPMENT COOLING SUPPLY FAN SYSTEM DEFERRED IAW ATI B767 MEL 21-58-03-01. MEL CAT C, CORRECTIVE ACTION DUE 1 DECEMBER 2025. AIRCRAFT RETURNED TO SERVICE. FWD RACK SUPPLY FAN REMOVED AND REPLACED IAW B767 AMM 21-58-06. OPERATIONAL CHECK GOOD, NO ADDITIONAL FAULTS NOTED. DEFERRAL MAINTENANCE ITEM 68109 CLEARED.

Incident date November 19, 2025
Airline IPXA
Flight MEL21
Aircraft BOEING 767300
Registration N376UP
Affected area Cockpit
Event type Smoke
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.