AIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED THAT THE APU DISCHARGE SWITCH LIGHT WAS ON IN FLIGHT. NO RELATED ECAM MESSAGES WERE NOTED. MAINTENANCE PERFORMED OPERATIONAL TEST OF THE APU FIRE EXTINGUISHING LOOP/SQUIB PER AMM 26-22-00 AND NO ISSUES WERE NOTED. MAINTENANCE REPORTED THAT THERE WAS NO DISCHARGE LIGHT ILLUMINATED PRIOR OR AFTER OPERATIONAL TEST.
| Incident date | October 28, 2025 |
|---|---|
| Airline | AALA |
| Flight | AMM26 |
| Aircraft | AIRBUS A319112 |
| Registration | N768US |
| Affected area | Engine |
| Event type | Fire |
| Verification | Official |