ELECTRICAL BURNING SMELL FLOM ROW 37 LOCATED ODOR TO AFT WAP OVER AFT GALLEY CEILING. PULLED & COLLARED CB AT P6-5 B-11. CREW WAP POWER. REF WDM 46-13-21-1. COMPLIED WITH MEL. REF AMM 46-13-06 FOR WAP 2 . VERIFIED NO OTHER SYSTEMS AFFECTED. COMPLIED WITH FIM 21-00 TASK 830. REMOVED CEILING PANELS ABOVE ROW 30 & 36 , LOWERED SEVERAL PSU PANELS IN AFT CABIN, NO EVIDENCE OF ANY ABNORMAL ODORS. EVIDENCE OF FAINT ELECTRICAL ODOR IN CEILING PANEL ABOVE AFT GALLEY, BUT NO EVIDENCE OF BURNING ODOR. R & R WAP IAW AMM TASK 46-13-06-400-801. OPS CHKD GOOD.

Incident date July 25, 2025
Airline CALA
Flight ROW37
Aircraft BOEING 7379
Registration N17595
Affected area Cabin
Event type Fumes or Odor
Verification Official