PASSENGERS ROW 43 A-C SMELLED FUMES 2X CONTCTD TOMC SUSPECTED DO OR HT DEBRIEFED CREW SMELL CAME AND WENT A FEW TIMES. SMOKE AND ODER QUESTIONAIRE ADDED. ON ARRIVAL AREAS HAD NO SMELLS, RAN GALLEY CHILLERS NO DEFECTS NOTED. RAN PANISONIC SYSTEMS AND HAD VENDOR CHECK SYSTEM, NO FAULTS OR DEFECTS NOTED. PERFORMED GALLEY HEAT SYSTEM TEST REF MM 25-30-F1 TEST PASSED AND NO SMELLS IN AREA DURING TEST. ADD EMP:U409087 PERFORMED CHECK OF TOILET SYSTEMS IN THAT AREA, NO SMELLS. PERFORMED GVI AND SMELL CHECK OF AFT EQUIPMENT BAY NO DEFECTS OR SMELLS. REF DMC-B787-A-21-20-F5-72A-421A-A NO PREVIOUS LEG FAULTS ON SYSTEMS RELATED, RAN PACKS WITH NO SMELLS. NO DEFECTS NOTED. OK FOR SERVI… REF MM 21-45-00 PASSENGER ENTRY DOOR AREA HEARING SYSTEM TEST. TEST PASSED.
| Incident date | May 20, 2025 |
|---|---|
| Airline | CALA |
| Flight | ROW43 |
| Aircraft | BOEING 7879 |
| Registration | N24988 |
| Affected area | Cabin |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: CALA fumes or odor report on 2025-05-20 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.