FLT ATNDTS DETCTD SMOKE ODOR NEAR DOOR 2R. 2R DOOR HEATER WAS TU RNED OFF. TOMC ADVISED CREW REPORTEDLY TURNED OF DOOR 2R HEATER AND ODOR DISSIPATED. (MC) PERFORMED SMOKE/ODOR IN CABIN CONDITIONAL INSPECTION IAW AMM 05-51-56-202-001-001 NO OTHER FAULTS NOTED. INSPECTED MID GALLEY OVENS AND BOTH LAVS WASTE BIN THERMAL TAPE. NO DEFECTS NOTED. INSPECTED ALL 6 MID DOOR SUPPLEMENTAL HEATERS (2 DOOR HEATER, 4 CEILING HEATERS) FOUND ALL WITHIN SERVICEABLE CONDITION EXCEPT RIGHT AFT CEILING HEATER. FOUND EXCESSIVE DUST COVERING INSIDE COILS. REMOVED AND REPLACED RIGHT AFT CEILING HEATER IAW AMM 21-45-41/404. PERFORMED OPS CHECK IAW AMM 21-45-705-001-001. OPS CHECK PA. OPS CHECK PASSED. NO BURNING SMELL PRESENT DURING OPS CHECK.
| Incident date | May 15, 2025 |
|---|---|
| Airline | CALA |
| Flight | AMM05 |
| Aircraft | BOEING 767424ER |
| Registration | N76055 |
| Affected area | Cabin |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: CALA fumes or odor report on 2025-05-15 (external.apic4e.faa.gov)
- FAA SDR: SWAA fumes or odor report on 2025-05-14 (external.apic4e.faa.gov)
- FAA SDR: SWAA fumes or odor report on 2025-05-14 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.