SHIP 5089 STRONG SMELL OF BURNING PLASTIC AFT GALLEY. TURNED OFF HOT PLATES NO EFFECT. TURNED OFF COMMERCIAL PRIOR-SMELL DISAPPEARED QRH COMPLIED WITH. CORRECTIVE ACTION: PERFORMED NO-GO ODI PROCEDURES. FOUND POTABLE WATER WITH HEAVY CHEMICAL SMELL IN COFFEE POTS AND WHEN USING GALLEY TAP WATER. EXAMINED ALL ELECTRICAL CONNECTIONS AND NO ISSUES FOUND. CONFIRMED WITH CREW OF WATER SMELL. DRAINED AND FILLED POTABLE WATER SYSTEM IAW A321 AMM 38-10 AFTER FULLY DEPLETING WATER. (6969940)

Incident date April 22, 2025
Airline DALA
Flight AMM38
Aircraft AIRBUS A321271NX
Registration N589DT
Affected area Cabin
Event type Smoke
Verification Official