IN DESCENT AROUND 11000 FT DIRTY SOCK SMELL FOLLOWED PROCEDURE ISOLATED PACK 1 AND SMELL DISIPATED ( PACKS – A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PACK FLOW SELECTOR) AND WITH MOD. 30626/MP K6443 (ENHANCED ECS) ). DESCRIPTION OF ODOR/FUMES: PERSISTENT, DIRTY SOCKS SMELL. APPARENT CABIN SOURCE: CABIN AIR SUPPLY VENTS. FLIGHT DECK. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION REQUIRED.-R/R PACK 1 COMPRESSOR OUTLET DUCT PACKINGS, CLAMP HALVES AND CLAMP IAW AMM 21-52-23. LEAK CHECK GOOD. NO FAULT NOTED. THIS CLEARS DMI. PLACARD REMOVED, MOC NOTIFIED.
| Incident date | April 18, 2025 |
|---|---|
| Airline | GTIA |
| Flight | TSM5 |
| Aircraft | AIRBUS A320271N |
| Registration | N970NK |
| Affected area | Cockpit |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: GTIA fumes or odor report on 2025-04-18 (external.apic4e.faa.gov)
- FAA SDR: GTIA fumes or odor report on 2025-04-19 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.