(AIRCRAFT GROUNDED) ODOR EVENT RETURNED, PERFORMED QRH , PACK 2 DEACTIVATED & ODOR WENT AWAY. DURING TSHOOTING AMM 49-00-00-200-811-A FOUND OIL IN FCU DRAIN PORT, R & R APU FCU IAW AMM 49-32-11-000-003-A-400-003-A. APU COOLING FAN HAD OIL ON BOTTOM OF UNIT & AROUND DUCTS, R & R CLEANED APU OIL COOLER FAN PER 3.C IN TC 21-000-002. NO LEAKS NOTED INSIDE OIL COOLING FAN. REINSTALLED COOLING FAN IAW AMM 49-52-51-400-002-A. REMOVED & CLEANED APU OIL COOLER FAN PER 3.C IN TC 21-000-002. NO LEAKS NOTED INSIDE OIL COOLING FAN. REINSTALLED COOLING FAN IAW AMM 49-52-51-400-002-A. DURING REPLACEMENT OF FUEL CONTROL UNIT, NOTED OIL WETTING ON OTBD SIDE OF OIL COOLER UNDER WELD. REPLACED APU OIL COOLER IAW AMM 49-91-44.

Incident date April 10, 2025
Airline WX0A
Flight WX0A
Aircraft AIRBUS A320214
Registration N283NV
Affected area Engine
Event type Fumes or Odor
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.