CA WINDOW HAD ELEC ARC IN FLIGHT. WINDOW BURNED AND DISCOLORED. CREW REPORTED ON CLIMB #1 WINDOW BEGAN ARCING AND THEN CRACKED. NO SMOKE OR ODOR REPORTED. CREW DID NOT NOTICE ANY WINDOW HEAT FAIL LIGHT. REMOVED CAPTAINS WINDOW PER AMM 56-11-11-000-801 ADD EMP:U118424 INSPECTED AND VERIFIED PROPER WINDOW TB TAP LOCATION REF AMM 30-41-21-000-801. REPLACED CAPTAINS NO. 1 WINDOW IN REFERENCE TO AMM 56-11-11-400-801 UP TO STEP 3.I.(16), OPERATIONAL TEST. SEALANT (PR1826 B1/4) APPLIED AT 0430 ON THE 13TH (4 HOUR CURE). CABIN PRESSURE LEAK TEST STILL NEEDED IN REFERENCE TO AMM WINDSHIELD, B73 OFF 99-5610-9-9001 7006 ON 99-5610-9-9001 9218 WINDSHIELD, B73 OFF 99-5610-9-9001 7006 ON 99-5610-9-9001 9218 05-51-91-790-801. ELOTO IS STILL CURRENTLY OPEN.PARTS USED: 99-5610-9-9001,QTY :1 ROTABLE PARTS CHANGE WAS INDICATED – TT # 1332931 SN OFF 7006 COMPLETED CAPTAINS WINDOW CHANGE PER AMM 56-11-11-400-801 FROM ITEM 3 I 16 TO COMPLETION. ACCOMPLISHED PRESSURIZATION CHECK OF WINDOW, NO LEAKS OR SQUEELS NOTED…ALL ELOTO BREAKERS RESET..
| Incident date | February 12, 2025 |
|---|---|
| Airline | CALA |
| Flight | AMM56 |
| Aircraft | BOEING 737824 |
| Registration | N17244 |
| Affected area | Cabin |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: CALA fumes or odor report on 2025-02-12 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.