SHIP 5657 APU FAULT CAUTION AND APU SHUTDOWN AT GATE. THIS WAS ACCOMPANIED BY A BURNING ODOR. CORRECTIVE ACTION: BITE TEST OF APU SHOWS AUTO SHUTDOWN FOR HIGH OIL TEMP. REPLACED OIL COOLER BY-PASS VALVE PER B-757 AMM 49-27. FOUND AIR INLET DUCT FOR OIL COOLER COLLAPSED INTERNALLY. REPLACED APU OIL COOLER SUPPLY DUCT- APU OPN NML. (6917476)

Incident date January 11, 2025
Airline DALA
Flight AMM49
Aircraft BOEING 757251
Registration N557NW
Affected area Engine
Event type Fumes or Odor
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.