CREW REPORTED- DURING CLIMB AROUND FL210, WE NOTICED SMOKE COMING OUT OF MOSTLY LEFT SIDE VENTS. APPROXIMATELY 10-15 SECS LATER, WE GOT A CALL FROM FA IN REGARDS TO SMOKE IN CABIN AROUND ROW 7-11 BOTH SIDES. PASSENGERS HEARD LOUD BANG AND METAL GRINDING NOISE POSSIBLY COMING WHERE THE GEARS ARE. CORR ACTION- NO EXTERNAL DEFECT FOUND. FURTHER GAINED ACCESS TO #1 ACM, PERFORMED GENERAL VISUAL INSPECTION. CHECKED FOR DEFECTS, EVALUATED AND FOUND DEBRIS INSIDE THE CONDENSER MIXER. REMOVED CONDENSER MIXER, ACM, DUAL HEAT EXCHANGER. INSTALLED CUSTOMER SUPPLIED OVERHAULED CONDENSER, ACM, DUAL HEAT EXCHANGER AND NEW BUTTERFLY VALVE. PERFORMED SATISFACTORY OPS CHECK. RESTORED ACCESS. OFF CONDENSER PN 816650-1 SN 20020286 AND OFF ACM PN 815240-3 SN 200105257

Incident date March 2, 2025
Airline 4DPA
Flight FL210
Aircraft EMB EMB145LR
Registration N962JX
Affected area Cabin
Event type Smoke
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.