INFLIGHT GOT ECAM: HOT AIR SUPPLY OVERHEAT, THEN GOT: MAIN DECK CARGO SMOKE – MID DECK B, THEN GOT BLEED VALVE ENG 2 FAULT. COMPLIED WITH ECAM CHECKLIST AND DECLARED EMERGENCY. WHILE LANDING GOT ENG 2 REV CONTROL CB POPPED (V74). EMERGENCY DECLARED. MAIN CARGO SMOKE DETECT UNITS 1WU, 2WU, 3WU, 4WU, 6WU, 8WU REPLACED. HOT AIR SUPPLY OVRHT POSSIBLY RELATED TO MAIN DECK CARGO SMOKE ALERT. REF MM 21-62-00-05 AIR SUPPLY OVERHEAT CHECKS NORMAL. REF MM 26-19-00-05, MAIN DECK CARGO SMOKE TEST GOOD. REF ITEM 3611/4099 FOR WIRE REPAIR RELATING TO ENG2 BLEED VLV OPERATION. REF MM 36-11-00-05, JRH CH 5, ENG2 BLEED VLV CHECKS GOOD DURING ENG RUN. OK FOR SERVICE.
| Incident date | April 2, 2025 |
|---|---|
| Airline | FDEA |
| Flight | ENG2 |
| Aircraft | AIRBUS A300F4605R |
| Registration | N685FE |
| Affected area | Cargo |
| Event type | Smoke |
| Verification | Official |
Sources
- FAA SDR: FDEA smoke report on 2025-04-02 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.