SMOKE/FUMES SMELLED ON FLIGHT DECK AND IN FORWARD GALLEY.FWD EQ EXH FAN STATUS MESSAGE. CREW AND FA'S AT FORWARD GALLEY SMELL ELECTRICAL ACRID SMELL ON AND OFF WITH AN ASSOCIATED VIBRATION AT RIGHT FORWARD GALLEY FLOOR. PERFORMED CONDITIONAL INSPECTION PER AMM 05-51-56, FOUND P6-4 C/B H21 POPPED, FWD EQUIPT COOLING EXT FAN. FAN IDENTIFIED AS SOURCE OF ODOR. REPLACED FAN PER AMM 21-58-06, OPS CKS COMPLETED. NO ADDITIONAL ODOR NOTICED.
| Incident date | August 24, 2025 |
|---|---|
| Airline | CALA |
| Flight | AMM05 |
| Aircraft | BOEING 767322 |
| Registration | N671UA |
| Affected area | Cockpit |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: CALA fumes or odor report on 2025-08-24 (external.apic4e.faa.gov)
- FAA SDR: CALA fumes or odor report on 2025-08-25 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.