WHILE DESCENDING THROUGH 13,000 OBSERVED MUSTY ODOR IN FD, TURNED OFF PACK 1 ODOR DISSIPATED. DESCRIPTION OF ODOR/FUMES: TEMPORARY, MUSTY DRY SMELL. APPARENT CABIN SOURCE: CABIN ITEM. FLIGHT DECK. NO VISIBLE SMOKE/HAZE. NO MEDICAL ATTENTION.-REF TSM 05-50-00-810-831-A PERFOMED LEVEL A DECONTAMINATION IAW AMM 21-00-00-615-802-A PERFOMED PACK BURN OUT IAW AMM 21-00-00-615 & R/R RECIRCULATION FILTERS IAW AMM 21-21-41. NODEFECTS NOTED ON ENG 1 , 2 OR APU NO FURTHER DEFECTS NOTED AT THIS TIME ACFT OK FOR CONT SERVICE
| Incident date | September 29, 2025 |
|---|---|
| Airline | GTIA |
| Flight | TSM05 |
| Aircraft | AIRBUS A320271N |
| Registration | N920NK |
| Affected area | Cockpit |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: GTIA fumes or odor report on 2025-09-29 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.