FLT#1552, RSW-HPN. "CABIN ODOR WITNESSED BY INFLIGHT CREW AT CRUISE. DIRTY SOCK PLASTIC BURNING AFT OF ROW 22 STRONGEST AFT GALLEY A.C LEFT; PERFORMED INFO NOTICE 2017-T015L. C/W APU COMPARTMENT INSPECTION NO OIL/FUEL LEAKS NOTED VISUAL OR WITH BLACK LIGHT. APU PREVIOUSLY REPLACED ON 10/10/2025 INSPECTED IFE SYS NO EXPOSED WIRING OR ELECTRICAL BURNS NOTED. PERFORMED ENG RUN UPS CYCLING PACKS AND ISOLATING ENG BLEED/ APU BLEED. NO SMELL NOTED. INSPECTED AFT GALLEY COFFEE MAKERS POTS FOUND BURNT COFFEE GRINDS ON BOTTOM AND WALLS OF POTS OF COFFEE MAKERS 404/403 WHEN OPS CHECKED COFFEE POTS EMIT BURNING/ ROAST SMELL. COMPLIED WITH INFORMATION NOTICE 2017-T015 SECTION A. ISOLATED FAULT TO TYPE 10. ODOR COMING FROM COFFEE POTS REF MDDR 4429374-1 FOR NEF APPLIED PER TSM 05-50-00-810-085-B. A.C IS OK FOR SVC"

Incident date October 20, 2025
Airline YENA
Flight ROW22
Aircraft AIRBUS A320232
Registration N599JB
Affected area Engine
Event type Fumes or Odor
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.