(AIRCRAFT NOT GROUNDED) ODOR REPORTED BY CABIN ON DECENT TO LANDING. PERFORMED LEVEL 1 DECONTAMINATION PER TASK CARD A32X-21-000-001 WITH ENGS ONLY. PERFORMED LEVEL A DECONTAMINATION OF ECS IAW AMM 21-00-00-615-802-A. NO ODOR NOTED. WHILE PERFORMING TC 05-000-011, APU FOUND TO BE LEAKING IN INLET. IAW TSR-1848 APU LUBE MODULE REQUIRES REPLACEMENT. REMOVED APU LUBE MODULE REF AMM 49-91-45-000-003-A. INSTALLED NEW APU LUBE MODULE IAW AMM 49-91-45-400-003-A AND REINSTALLED FCU IAW AMM 49-32-11-400-003-A. OPS AND LEAK CHECK GOOD.
| Incident date | November 13, 2025 |
|---|---|
| Airline | WX0A |
| Flight | WX0A |
| Aircraft | AIRBUS A320214 |
| Registration | N276NV |
| Affected area | Engine |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: WX0A fumes or odor report on 2025-11-13 (external.apic4e.faa.gov)