THICK ACCURATE (ELECTRICAL/MECHANICAL SMELL) SMOKE COMING FROM THE VENTS IN THE CABIN AND FLIGHT DECK DURING CLIMBOUT. DEICED WITH TYPE 1 AND 4 PRIOR TO DEPARTURE. CAPTAIN SAID IT WASN’T DEICE FLUID SMELL. OCCURRED ON GEAR UP AROUND 700 FEET NOTICED SMOKE COMING FROM VENTS. APU WAS SUPPLYING BLEED. #1 AND #2 ENGINE BLEEDS WERE OFF. FLIGHT CREW DONNED O2 MASK. PASSENGER DID NOT. BY THE TIME DONNED THE O2 MASK AND PUTTING ON THE SMOKE GOGGLES, THE SMOKE DISSIPATED. FLIGHT CREW DID NOT REMEMBER SEEING ANY EICAS MESSAGES. BOTH PACKS WERE RUNNING. SINK RATE ON LANDING WAS LESS THAN 6FPS . NO OVERWEIGHT LANDING REQUIRED. PERFORMED FIM. INSPECTED BOTH LH AND RH AIR CYCLE MACHINES, NO FAULTS FOUND. INSPECTED LH AND RH COCKPIT RELAY SUPPORTS, NO FAULTS FOUND. PERFORMED INSPECTION OF APU INLET AND APU COWLING AND FOUND DEICING FLUID INGESTION. REMOVED ALL DEICING FLUID CONTAMINATION. RAN BOTH PACKS WITH BLEEDS ON. OPS CHECK SAT. NO FURTHER DEICING FLUID SMELL OR SMOKE COMING FROM COCKPIT OR CABIN VENTS. SERVICED O2 TO 1700 PSI. RETURNED SMOKE GOGGLES AND O2 MASKS TO ORIGINAL CONFIG. NO FURTHER DEFECTS NOTED AT THIS TIME.

Incident date March 2, 2026
Airline JJBA
Flight AND4
Aircraft EMB EMB145XR
Registration N17169
Affected area Cockpit
Event type Smoke
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.

Leave a Reply

Your email address will not be published. Required fields are marked *