DO THE SMOKE OR FUMES IN THE CABIN, SOURCE UNKNOWN – FAULT ISOLATION PER FIM 21-00 TASK 806. TOMC PL CREW BRIEFED THAT SMELL WAS COMING FROM LAV E, SAID THEY BELIVE THE SMELL WAS COMING FROM UNDER THE SINK. FOUND CB 18-3 F15 LAVATORY E WATER HEATER POPPED. PUSH IN BREAKER & WATER HEATER DOES NOT INDICATE ANY POWER. BELIEVE ODOR OF ELECTRICAL BURNING WAS CAUSED BY LAV E WATER HEATER SYSTEM, FURTHER TROUBLESHOOTING REQUIRED, R & R WATER HEATER ON LAV E, REF. AMM 38-13-01 OPS CHECK GOOD AT THIS TIME. AFTER REPLACEMENT OF WATER HEATER, LEFT WATER HEATER & APU POWER ON FOR AN EXTENDED AMOUNT OF TIME AND COULD NOT DUPLICATE SMOKE OR FUMES SMELL IN THE ACFT.

Incident date April 30, 2026
Airline CALA
Flight FIM21
Aircraft BOEING 737924ER
Registration N61882
Affected area Engine
Event type Fumes or Odor
Verification Official