SMOKE/FUME EVENT AFT GALLEY (10K THROUGH LANDING). C/A: PERFORMED INITIAL INSPECTION OF NR 1 , NR 2 ENG AND APU COMPARTMENT NO EXTERNAL LEAKS NOTED. (WIP D.P 098218). PERFORMED W/C 0550- 2001, LOGGED DATA WITH PTRAK , RESULTS SUBMITTED TO SMOKE AND FUMES GROUP, SPIKE IN DATA ON APU AND ENG#1 . PERFORMED W/C 4900 -2001, FOUND APU OIL OVERSERVICED, NO FURTHER DISCREPANCIES ON APU INSP. REMOVED ENG#1 HP VALVES, INSPECTED VALVE AND DUCTS NO OIL CONTAMINATION FOUND. REINSTALLED REF A320AMM 36-11 OPS AND LEAK CHECK GOOD. PERFORMED LEVEL A ECS DECONTAMINATION PER W/C 2100-2007 PERFORMED WC 0550-2001 AGAIN NO SPIKE IN APU DATA ENG #1 REMAINS HIGH, DATA SUBMITTED TO SMOKE AND FUMES GROUP. FOUND PACK #1 CONTAMINATED, PERFORMED LEVEL B DECONTAMINATION PER W/C 2100-2005 NO SMELL WITH ENGINE AND APU BLEED DURING VERIFICATION FOR ODOR. (LP: 8678694, AIRCRAFT WA GROUNDED)
| Incident date | June 12, 2026 |
|---|---|
| Airline | DALA |
| Flight | NR1 |
| Aircraft | AIRBUS A320212 |
| Registration | N356NW |
| Affected area | Engine |
| Event type | Fumes or Odor |
| Verification | Official |
Sources
- FAA SDR: DALA fumes or odor report on 2026-06-12 (external.apic4e.faa.gov)
This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.