FLIGHT 2116. APU IS LEAKING OIL RAMP REPORTED SMOKE FROM APU. REMOVED FROM SERVICE AND PLACED ON MEL 49-00-00. RETURNED TO SERVICE. MEL CLEARED 6/26 BY PERFORMING APU OIL SYS INSP IAW AMM 49-90-00-200-801-A, FOUND NO LEAKS. RAN APU, COULD NOT REPLICATE DEFECT. UPON GVI OF ACFT TAIL, FOUND TRAIL OF HYD FLUID COMING FROM BELLY OF ACFT. SUSPECT RESIDUE & SMOKE IS FROM HYD FLUID IAW AML 1152720, NR 1 HYD QTY IS LOW IN CRUISE. NFDN. PLACARDS PULLED, MX PROCEDURES REVERSED. CLEARS MEL. REMOVED HYD SYS 1 ACCESS PANEL 195DL & FOUND ECOLOGY BOTTLE FULL, DRAINED HYD SYS 1 ECOLOGY BOTTLE IAW AMM 12-12-11-600-801-A. CLEANED AREA AROUND HYD SYS 1 AS REQ & PERFORMED LEAK CHK. NO OBVISIOUS LEAKS NOTED. SERVICED HYD SYS 1 TO LIMITS IAW AMM 12-12-01-600-801-A. RAN BOTH ENGS & ACTUATED ALL FLT CONTROLS. NO LEAKS FOUND. HYD SYS 1 QTY REMAINED STEADY. REINSTALLED HYD SYS 1 ACCESS PANEL 195DL AS REQ. NFDN. ACFT OK FOR SERVICE.

Incident date June 26, 2026
Airline QXEA
Flight MEL49
Aircraft EMB ERJ170200LR
Registration N658QX
Affected area Engine
Event type Smoke
Verification Official

Sources

This entry summarizes publicly reported information and links to the original reporting or official record. Details can change as authorities and operators release additional information.